Procedure for the quantification of the biomarker (2-methoxyethoxy)acetic acid in human urine samples |
| |
Authors: | B'Hymer C Cheever K L Butler M A Brown K K |
| |
Affiliation: | Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Cincinnati, OH 45226, USA. cbhymer@cdc.org |
| |
Abstract: | An accurate and precise procedure was developed for the detection and quantification of (2-methoxyethoxy)acetic acid (MEAA), a metabolite and biomarker for human exposure to 2-(2-methoxyethoxy)ethanol. The compound 2-(2-methoxyethoxy)ethanol has a wide array of industrial applications including its use as an additive in military jet fuel. Exposure to 2-(2-methoxyethoxy)ethanol is a health concern owing to its toxicity which includes developmental and teratogenic properties. Sample preparation consisted of liquid-liquid extraction (LLE) and esterification of MEAA to produce the ethyl ester. Measurement was by a gas chromatograph (GC) equipped with a mass selective detector (MSD) using a HP-1 capillary column. Recovery studies of spiked blank urine demonstrated good accuracy and precision; recovery varied between 95 and 103% with relative standard deviations of 8.6% and less. The limit of detection (LOD) for this procedure was found to range from 0.02 to 0.08 microg/ml equivalent levels of MEAA in urine. These data and other aspects of the validation of this procedure will be discussed. |
| |
Keywords: | (2-Methoxyethoxy)acetic acid |
本文献已被 ScienceDirect PubMed 等数据库收录! |