Simple in vivo bioassay without radioisotopes for recombinant human erythropoietins.
Authors:T Hayakawa  M Wada  K Mizuno  S Abe  M Miyashita  M Ueda
Institution:National Institute of Hygienic Sciences, Tokyo, Japan.
Abstract:A simple in vivo bioassay suitable for routine testing of quality control of recombinant human erythropoietin (rHuEPO) analogues was developed. The assay took four days, normal mice were used and radioactive compounds were not needed. EPO activity was measured by the increased number of some part of reticulocytes which increased specifically and dose-dependently by the injection of rHuEPO. They were considered to be mostly immature reticulocytes and were counted as the residual particles from blood cells after treatment with a hemolysing reagent. These particles could be counted by conventional automated microcell counters. The assay procedure was simple and easy. The sensitivity, reliability and reproducibility of this method were acceptable for routine in vivo bioassay of rHuEPOs. This method was economical, and can be used instead of the existing bioassays for rHuEPOs.