首页 | 本学科首页   官方微博 | 高级检索  
     


The harmful effect of removing the extracellular vitrification medium during embryo cryopreservation using a nylon mesh device in rabbit
Affiliation:1. Department of Comparative Biomedicine and Food Science, University of Padua, Viale dell''Università 16, 35020 Legnaro, Padova, Italy;2. Information Engineering Department, University of Padua, Via Gradenigo, 6/, 35131 Padova, Italy;3. Department of Animal Pathology, University of Turin, via L. da Vinci 44, 10095, Grugliasco, Italy;1. Instituto Superior de Investigaciones Biológicas (INSIBIO), CONICET-UNT;2. Instituto de Biología “Dr. Francisco D. Barbieri”, Facultad de Bioquímica, Química y Farmacia, Universidad Nacional de Tucumán. Chacabuco 461, T4000ILI – San Miguel de Tucumán, Argentina
Abstract:During the last decades, many techniques have been developed to reduce sample volume and improve cooling and warming rates during embryo vitrification. The vast majority are based on the “minimum drop size” concept, in which the vitrification solution around embryos is reduced by aspiration, leaving a tiny part of volume surrounding embryos. However, novel cryodevices were aimed to remove the entire vitrification solution. This study was designed to compare the “minimum drop size” technique using Cryotop® with the nylon mesh as cryodevice on rabbit morula embryos. The outcomes assessed were the in vitro development rates (experiment 1) and the offspring rates at birth (experiment 2). Embryos were vitrified in a two-step procedure; equilibrium (10% EG + 10% Me2SO) for 2 min and vitrification (20% EG + 20% Me2SO) for 1 min. In experiment 1, embryos (n = 323) were warmed and subsequently in vitro cultured for 48 h to assess the embryo developmental capability to reach the hatching-hatched blastocyst stage. In experiment 2, embryos were transferred using the laparoscopic technique (n = 369) to assess the offspring rate at birth. In this context, rates of in vitro embryo development were similar between vitrified groups (0.73 ± 0.042% and 0.66 ± 0.047% for Cryotop® and nylon mesh device, respectively), but lower than in the fresh group (0.97 ± 0.016%, p < 0.05). In experiment 2, there were no significant differences in survival rates (offspring born/total embryos transferred) among the Cryotop® device group and fresh group (0.41 ± 0.049% and 0.49 ± 0.050%, respectively). But significantly lower value was obtained in the nylon mesh device group (0.18 ± 0.030%). These results indicate that nylon mesh is not suitable as cryodevice for rabbit morula vitrification, remaining those using the “minimum drop size” methodology as the best option.
Keywords:Rabbit  Vitrification  Device  Nylon  Cryotop
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号