Evaluation of the effect of silicone breast inserts on X-ray mammography and breast tomosynthesis images: A Monte Carlo simulation study
Institution:1. Department of Medical Physics, School of Medicine, University of Patras, Patras, Greece;2. Department of Medical Electronics, Technical University of Varna, Varna, Bulgaria;1. Cardiology Department, Policlinico of Bari Hospital, Bari, Italy;2. Department of Cardiovascular Medicine, Catholic University, Rome, Italy;3. Department of Clinical and Experimental Medicine, University of Insubria and Ospedale di Circolo, Varese, Italy;4. Department of Cardiac, Thoracic, and Vascular Sciences, Padua University Hospital, Padua, Italy;5. Department of Clinical and Experimental Medicine and Division of General Cardiology, University of Florence and AOU Careggi, Florence, Italy
Abstract:PurposeBreast augmentation is one of the most popular cosmetic surgeries worldwide. The aim of this study is to investigate the effect of breast implant insertion on the detectability and visibility of lesions on mammography and breast tomosynthesis (BT) images.Materials and methodsThree software phantoms, composed of a homogeneous background with embedded silicone gel structures, and two types of breast abnormalities, microcalcifications (µCs) and masses, were generated. Two X-ray breast imaging modalities were simulated: mammography and BT with six incident monochromatic X-ray beams with energies in the interval between 20 and 30 keV. Projection images were generated using an in-house developed Monte Carlo simulator. The detectability of mammographic findings adjacent to the implant material and the influence of the incident beam energy and implant thickness on the feature detection were studied.ResultsIt was found that implants thicker than 26 mm for the case of mammography and 14 mm for the case of BT obscured the visibility of underlying structures. Although BT demonstrated a lack of contrast, this modality was able to visualize µCs under considerable depths of implant. Increasing the incident beam energy led to better visualization of small µCs, while in the case of breast masses, their detectability was limited.ConclusionsSilicone gel implants introduce a limitation in the image quality of mammograms resulting in low detectability of features. In addition, silicone gel implants obscure partially or totally parts of the image, depending on the size and the thickness of the implant as well the energy of the X-rays used.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号