首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Fluorescent siderophore-based chemosensors: iron(III) quantitative determinations
Authors:Tania Palanché  Frank Marmolle  Mohamed A Abdallah  Abraham Shanzer  A-M Albrecht-Gary
Institution:(1) Laboratoire de Physico-Chimie Bioinorganique UMR 7512 CNRS, Faculté de Chimie, 1 rue Blaise Pascal F-67000 Strasbourg, France e-mail: amalbre@chimie.u-strasbg.fr Fax: +33-388-604392, FR;(2) Laboratoire de Chimie Microbienne, UMR 7509 CNRS Ecole Supérieure de Biotechnologie de Strasbourg F-67400 Illkirch, France, FR;(3) Department of Organic Chemistry, The Weizmann Institute of Science, Rehovot, Israel 76100, IL
Abstract: A highly sensitive and selective method is described for a rapid and easy determination of iron(III). This procedure is based on fluorimetric detection combined with the attractive properties of siderophores and biomimetic ligands, which are strong and selective ferric chelators. Azotobactin δ, a bacterial fluorescent siderophore, three fluorescent derivatives of desferriferrioxamine B with a linear structure (NBD-, MA-, NCP-desferriferrioxamine B) and one tripodal biomimetic ligand of desferriferrichrome carrying an anthracenyl fluorescent probe were examined. A very efficient static quenching mechanism by iron was observed for all the ligands considered in this work. Our results identify azotobactin δ as the most promising chemosensor of ferric traces in water, more sensitive than the NBD-desferriferrioxamine B fluorescent ligand. Under more lipophilic conditions, the anthryl-desferriferrichrome biomimetic analogue showed similar analytical potential and was found to be more sensitive than the lipophilic MA- and NCP-desferriferrioxamine B. Their detection limits were respectively 0.5 ng mL–1 for azotobactin δ and 0.6 ng mL–1 for the anthryl tripodal chelator. The calibration curves were linear over the range 0–95 ng mL–1 and 0–180 ng mL–1. Various foreign cations have been examined and only copper(II) and aluminium(III) were shown to interfere when present in similar concentrations as iron(III). The developed procedure using fluorescent siderophores or biomimetic ligands of iron(III) may be applied (1) to monitor iron(III)-dependent biological systems and (2) to determine iron(III) quantitatively in natural waters and in biological systems. Received: 12 September 1998 · Accepted: 19 January 1999
Keywords:  Iron(III) determination  Fluorescence  Siderophores  Azotobactin  Trihydroxamate ligands
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号