Reactivities of organic phase biosensors: 6. Square-wave and differential pulse studies of genetically engineered cytochrome P450(cam) (CYP101) bioelectrodes in selected solvents
Authors:Iwuoha Emmanuel I  Smyth Malcolm R
Institution:Department of Chemistry, University of Western Cape, Bellville 7535, South Africa. eiwuoha@uwc.ac.za
Abstract:Cytochrome P450(cam) (CYP101) bioelectrodes suitable for application in organic phases were prepared from genetically engineered CYP101 and vesicular dispersions of didodecyldimethylammonium bromide. The amperometric biosensor system was characterised under anaerobic conditions by cyclic and square-wave voltammetric methods. Cyclic- and square-wave-voltammetry studies showed that the biosensors exhibited direct reversible electron transfer between the haem iron atom and the glassy carbon electrode surface. The formal redox potential estimated for the electrode in acetonitrile was -380 mV/Ag-AgCl. The formal potential shifted anodically as the organic phase biosensor responded irreversibly to substrate (camphor) under anaerobic and aerobic conditions in acetonitrile. Differential pulse analysis of the reactivities of the CYP101 enzyme electrode confirmed the square-wave voltammetry result, which showed that the binding of substrate decreased the redox potential necessary for initiating the monooxygenation reaction of cytochrome P450(cam).