Polyethylene glycol-stabilized lipid disks as model membranes in interaction studies based on electrokinetic capillary chromatography and quartz crystal microbalance |
| |
Authors: | Vainikka Kati Reijmar Karin Yohannes Gebrenegus Samuelsson Jörgen Edwards Katarina Jussila Matti Riekkola Marja-Liisa |
| |
Institution: | aLaboratory of Analytical Chemistry, Department of Chemistry, University of Helsinki, FIN-00014 Helsinki, Finland;bDepartment of Physical and Analytical Chemistry, Physical Chemistry, Uppsala University, SE-75123 Uppsala, Sweden;cDepartment of Physical and Analytical Chemistry, Analytical Chemistry, Uppsala University, SE-75124 Uppsala, Sweden;dFreiburg Institute for Advanced Studies (FRIAS), School of Soft Matter Research, University of Freiburg, D-79104 Freiburg, Germany |
| |
Abstract: | Distearoylphosphatidylcholine (DSPC)/cholesterol/distearoylphosphatidylethanolamine (DSPE)–polyethylene glycol 5000 PEG(5000)] lipid disks, mimicking biological membranes, were used as pseudostationary phase in partial filling electrokinetic capillary chromatography (EKC) to study interactions between pharmaceuticals and lipid disks. Capillaries were coated either noncovalently with a poly(1-vinylpyrrolidone)-based copolymer or covalently with polyacrylamide to mask the negative charges of the fused-silica capillary wall and to minimize interactions between positively charged pharmaceuticals and capillary wall. Although the noncovalent copolymer coating method was faster, better stability of the covalent polyacrylamide coating at physiological pH 7.4 made it more reliable in partial filling EKC studies. Migration times of pharmaceuticals were proportional to the amount of lipids in the pseudostationary phase, and partition coefficients were successfully determined. Because the capillary coatings almost totally suppressed the electroosmotic flow, it was not practical to use the EKC-based method for partition studies involving large molecules with low mobilities. Hence, the applicability of the biomembrane mimicking lipid disks for interactions studies with large molecules was verified by the quartz crystal microbalance technique. Biotinylated lipid disks were then immobilized on streptavidin-coated sensor chip surface, and interactions with a high-molecular-mass molecule, lysozyme, were studied. Cryo-transmission electron microscopy and asymmetrical flow field-flow fractionation were used to clarify the sizes of lipid disks used. |
| |
Keywords: | Electrokinetic capillary chromatography Partial filling technique Bilayer disks Pharmaceuticals Partition coefficient |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|