首页 | 本学科首页   官方微博 | 高级检索  
     


A New Approach to Assess the Gastrocnemius Muscle Volume in Rodents Using Ultrasound; Comparison with the Gastrocnemius Muscle Index
Authors:Tim H. J. Nijhuis  Siebe A. S. de Boer  Abhijeet L. Wahegaonkar  Allen T. Bishop  Alexander Y. Shin  Steven E. R. Hovius  Ruud W. Selles
Affiliation:1. Department of Plastic, Reconstructive and Hand Surgery, Erasmus MC, University Medical Center, Rotterdam, The Netherlands.; 2. Department of Orthopaedic Surgery, Division of Hand Surgery, Mayo Clinic, Rochester, Minnesota, United States of America.; 3. Microvascular Research Laboratory, Mayo Clinic, Rochester, Minnesota, United States of America.; Creighton University, United States of America,
Abstract:

Introduction

The purpose of this study was to determine the reliability and validity of a new non-invasive ultrasound technique to measure gastrocnemius muscle atrophy after nerve denervation in an animal model.

Methods

In sixteen rodents an eight mm sciatic nerve gap was created. In the following 8 weeks, each week, two rodents were euthanized and the gastrocnemius muscle was examined using two different ultrasound systems and two investigators. The standardized ultrasound measurement protocol consisted of identifying pre-defined anatomical landmarks: 1) the fibula, 2) the fibular nerve, and 3) the junction between the most distal point of the semitendinosus muscle and gastrocnemius muscle. Consequently, we measured the muscle thickness as the length of the line between the fibula and the junction between the two muscles, perpendicular to the fibular nerve. After the ultrasound recording, the muscle mass was determined.

Results

A steep decline of muscle weight of 24% was observed after one week. In the following weeks, the weight further decreased and then remained stable from 6 weeks onwards, resulting in a maximal muscle weight decrease of 82%. The correlation coefficient was >0.96 between muscle diameter and weight using both ultrasound systems. The inter-rater reliability was excellent for both devices on the operated side (ICC of 0.99 for both ultrasound systems) and good for the non-operated site (ICC’s: 0.84 & 0.89). The difference between the muscle mass ratio and the muscle thickness ratio was not more than 5% with two outliers of approximately 13%.

Discussion

We have developed an innovative, highly reliable technique for quantifying muscle atrophy after nerve injury. This technique allows serial measurements in the same animal over time. This is a significant advantage compared to the conventional technique for quantifying muscle atrophy, which requires sacrificing the animal.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号