首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Neutrophil-bead collision assay: pharmacologically induced changes in membrane mechanics regulate the PSGL-1/P-selectin adhesion lifetime
Authors:Edmondson K E  Denney W S  Diamond S L
Institution:Institute for Medicine and Engineering, Department of Bioengineering, University of Pennsylvania, 3320 Smith Walk, Philadelphia, PA 19104, USA.
Abstract:Visualization of flowing neutrophils colliding with adherent 1-mum-diameter beads presenting P-selectin allowed the simultaneous measurement of collision efficiency (epsilon), membrane tethering fraction (f), membrane tether growth dynamics, and PSGL-1/P-selectin binding lifetime. For 1391 collisions analyzed over venous wall shear rates from 25 to 200 s(-1), epsilon decreased from 0.17 to 0.004, whereas f increased from 0.15 to 0.70, and the average projected membrane tether length, L(tether)(m), increased from 0.35 mum to approximately 2.0 mum over this shear range. At all shear rates tested, adhesive collisions lacking membrane tethers had average bond lifetimes less than those observed for collisions with tethers. For adhesive collisions that failed to form membrane tethers, the regressed Bell parameters (consistent with single bond Monte Carlo simulation) were zero-stress off-rate, k(off)(0) = 0.56 s(-1) and reactive compliance, r = 0.10 nm, similar to published atomic force microscopy (AFM) measurements. For all adhesion events (+/- tethers), the bond lifetime distributions were more similar to those obtained by rolling assay and best simulated by Monte Carlo with the above Bell parameters and an average of 1.48 bonds (n = 1 bond (67%), n = 2 (22%), and n = 3-5 (11%)). For collisions at 100 s(-1), pretreatment of neutrophils with actin depolymerizing agents, latrunculin or cytochalasin D, had no effect on epsilon, but increased L(tether)(m) by 1.74- or 2.65-fold and prolonged the average tether lifetime by 1.41- or 1.65-fold, respectively. Jasplakinolide, an actin polymerizing agent known to cause blebbing, yielded results similar to the depolymerizing agents. Conversely, cholesterol-depletion with methyl-beta-cyclodextrin or formaldehyde fixation had no effect on epsilon, but reduced L(tether)(m) by 66% or 97% and reduced the average tether lifetime by 30% or 42%, respectively. The neutrophil-bead collision assay combines advantages of atomic force microscopy (small contact zone), aggregometry (discrete interactions), micropipette manipulation (tether visualization), and rolling assays (physiologic flow loading). Membrane tether growth can be enhanced or reduced pharmacologically with consequent effects on PSGL-1/P-selectin lifetimes.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号