首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Crossflow microfiltration of recombinant Escherichia coli lysates after high pressure homogenization
Authors:Bailey S M  Meagher M M
Institution:Department of Biological Systems Engineering, University of Nebraska, Lincoln, Nebraska 68583.
Abstract:Crossflow membrane filtration was used to process recombinant Escherichia coli cell lysates containing protein inclusion bodies after high pressure homogenization. The number of passes through the high pressure homogenizer changed the viscosities and average particle sizes of the cell lysates. The different cell lysates were processed with a hollow fiber unit containing microfiltration membranes and a plate and frame unit with either ultrafiltration or microfiltration membranes. There were differences in permeate flux and protein transmission for the various membranes with the best performing membranes giving permeate fluxes greater than 60 L m(-2) h(-1) and protein transmissions greater than 90%. For a given membrane, no differences were observed between the cell lysates following homogenization with one, two, and three passes at 83 MPa. The lack of a difference between the three lysates is due to their similarities with respect to the released macromolecules and the presence of small (<0.1 mum) cell debris. (c) 1997 John Wiley & Sons, Inc. Biotechnol Bioeng 56: 304-310, 1997.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏