首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Determination of ammonium and L-Glutamine in hybridoma cell cultures by sequential flow injection analysis
Authors:Carles Campmajó  Jordi Joan Cairó  Anna Sanfeliu  Esteve Martínez  Salvador Alegret  Francesc Gòdia
Institution:(1) Unitat d'Enginyeria Química, Universitat Autònoma de Barcelona, 08193 Bellaterra, Barcelona, Spain;(2) Unitat de Química Analítica, Universitat Autònoma de Barcelona, 08193 Bellaterra, Barcelona, Spain
Abstract:A flow injection anlytical system based on a gas diffusion membrane module for ammonia and an ammonium flow-through potentiometric detector has been set up for measurement of L-glutamine and ammonium ions in hybridoma cell cultures. The main feature of the system is that the same basic analytical concept and equipment is used in both measurements, the only difference being for the determination of L-glutamine, in which the sample flows through an immobilized glutaminase cartridge. The conditions to enable the performance of both analysis consecutively, avoiding potential interferences by unwanted deamination of other compounds in the samples, have been determined. Finally, the proposed system has been compared with reference analytical methods for batch hybridoma cell culture experiments.
Keywords:flow injection analysis  ammonium  L-glutamine  sequential determination  hybridoma culture
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏