首页 | 本学科首页   官方微博 | 高级检索  
     


Oak leaves as aerosol collectors: relationships with wind velocity and particle size distribution. Experimental results and their implications
Authors:Ausra Reinap  Bo L. B. Wiman  Birgitta Svenningsson  Sara Gunnarsson
Affiliation:(1) Natural Resources Management Research Unit, Environmental Science and Technology Research Centre, School of Pure and Applied Natural Sciences, Kalmar University, 391 82 Kalmar, Sweden;(2) Department of Physical Geography and Ecosystems Analysis, Lund University, Lund, Sweden;(3) Department of Nuclear Physics, Lund University, Lund, Sweden;
Abstract:Advancing the understanding of the aerosol-capture efficiencies of forest components such as leaves and needles, and of the mechanisms that underpin these efficiencies, is essential to the many related issues of forest turnover of nutrients and pollutants. For idealized collectors (such as artificial plates or cylinders) aerosol-mechanics offers a means for calculating capture efficiencies. For living collectors, in particular deciduous leaves, experimental investigations become necessary to assist in formulating the sub-models of capture efficiency that are fundamental to the modelling of fluxes of aerosol-borne substances to forests. We here present wind-tunnel based methods and results for leaves of Quercus robur L. exposed to an aerosol whose mass versus aerodynamic particle size distribution is characterised by a geometric mean aerodynamic particle diameter around 1.2 μm and a geometric standard deviation around 1.8. With respect to that distribution, and founded on a specially designed leaf wash-off method, we obtained average oak-leaf capture efficiencies ranging from 0.006% of the approaching aerosol mass flux at wind-speed 2 ms−1 to 0.012% of the flux at wind-speeds 10 ms−1, respectively. These values can be translated into deposition velocities (V d ) for a leaf ensemble with a given leaf area index (LAI). With LAI in the range 2–5 (commonly found in the field) and for wind-speeds 2, 5 and 10 ms−1, resulting V d -values would be 0.02–0.05, 0.05–0.13, and 0.2–0.6 cm/s, respectively. To the extent comparisons are possible, our capture efficiency values are at the low end of the range of values reported by other researchers. The strong wind-speed sensitivity of V d has implications for the deposition of aerosol-borne substances to forests for which wind regimes may shift as a result of climatic and land-use changes.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号