Rapid and sensitive high-performance liquid chromatographic assay for 6-hydroxychlorzoxazone and chlorzoxazone in liver microsomes |
| |
Authors: | Sridar V Chittur Timothy S Tracy |
| |
Affiliation: | Department of Basic Pharmaceutical Sciences, School of Pharmacy, West Virginia University, Box 9530, Morgantown, WV 26506, USA |
| |
Abstract: | A high-performance liquid chromatographic assay was developed for the quantitation of chlorzoxazone and its major metabolite 6-hydroxychlorzoxazone. These compounds along with phenacetin, the internal standard, were extracted from incubation mixtures using ether extraction. The extracts were analyzed on a Brownlee Spheri-5 C8 column with a mobile-phase of acetonitrile–0.5% phosphoric acid (30:70, v/v). The assay utilized UV detection at 287 nm which provided sensitivity and specificity to simultaneously quantify chlorzoxazone and 6-hydroxychlorzoxazone from liver microsomal samples at amounts of 10 ng and greater. The mean correlation coefficient of the standard curves for 6-hydroxychlorzoxazone and chlorzoxazone was 0.998 and 0.993, respectively, over the range of 25–400 ng, and the regression curves were found to be linear at least through 1600 ng. All components eluted within 7 min, resulting in a total analysis time of 8 min. The inter-day and intra-day coefficients of variation were <7 and <3%, respectively. This method provides a rapid, sensitive and cost-effective assay for 6-hydroxychlorzoxazone and chlorzoxazone in liver microsomal incubations. |
| |
Keywords: | 6-Hydroxychlorzoxazone Chlorzoxazone |