首页 | 本学科首页   官方微博 | 高级检索  
     


Simultaneous determination of azathioprine and 6-mercaptopurine by high-performance liquid chromatography
Authors:Erik C. Van Os   Jeffrey A. McKinney   Bradley J. Zins   Dennis C. Mays   Zachary H. Schriver   William J. Sandborn  James J. Lipsky
Abstract:A specific, sensitive, single-step solid-phase extraction and reversed-phase high-performance liquid chromatographic method for the simultaneous determination of plasma 6-mercaptopurine and azathioprine concentrations is reported. Following solid-phase extraction, analytes are separated on a C18 column with mobile phase consisting of 0.8% acetonitrile in 1 mM triethylamine, pH 3.2, run on a gradient system. Quantitation limits were 5 ng/ml and 2 ng/ml for azathioprine and 6-mercaptopurine, respectively. Peak heights correlated linearly to known extracted standards for 6-mercaptopurine and azathioprine (r = 0.999) over a range of 2–200 ng/ml. No chromatographic interferences were detected.
Keywords:Azathioprine   6-Mercaptopurine
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏