Reconstruction of orbital floor fracture using solvent-preserved bone graft
Authors:Yavuzer Reha  Tuncer Serhan  Başterzi Yavuz  Işik Ipek  Sari Alper  Latifoğlu Osman
Affiliation:Plastic, Reconstructive, and Aesthetic Surgery Department, Gazi University Faculty of Medicine, Ankara, Turkey. ryavuzer@hotmail.com
Abstract:The orbital floor is one of the most frequently damaged parts of the maxillofacial skeleton during facial trauma. Unfavorable aesthetic and functional outcomes are frequent when it is treated inadequately. The treatment consists of spanning the floor defect with a material that can provide structural support and restore the orbital volume. This material should also be biocompatible with the surrounding tissues and easily reshaped to fit the orbital floor. Although various autografts or synthetic materials have been used, there is still no consensus on the ideal reconstruction method of orbital floor defects. This study evaluated the applicability of solvent-preserved cadaveric cranial bone graft and its preliminary results in the reconstruction of the orbital floor fractures. Twenty-five orbital floor fractures of 21 patients who underwent surgical repair with cadaveric bone graft during a 2-year period were included in this study. Pure blowout fractures were determined in nine patients, whereas 12 patients had other accompanying maxillofacial fractures. Of the 21 patients, 14 had clinically evident diplopia (66.7 percent), 12 of them had enophthalmos (57.1 percent), and two of them had gaze restriction preoperatively. Reconstruction of the floor of the orbit was performed following either the subciliary or the transconjunctival approach. A cranial allograft was placed over the defect after sufficient exposure. The mean follow-up period was 9 months. Postoperative diplopia, enophthalmos, eye motility, cosmetic appearance, and complications were documented. None of the patients had any evidence of diplopia, limited eye movement, inflammatory reactions in soft tissues, infection, or graft extrusion in the postoperative period. Providing sufficient orbital volume, no graft resorption was detected in computed tomography scan controls. None of the implants required removal for any reason. Enophthalmos was seen in one patient, and temporary scleral show lasting up to 3 to 6 weeks was detected in another three patients. Satisfactory cosmetic results were obtained in all patients. This study showed that solvent-preserved bone, which is a nonsynthetic, human-originated, processed bioimplant, can be safely used in orbital floor repair and can be considered as another reliable treatment alternative.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号