Comparison of the measured and calculated time profiles of the leakage current in the magnetically insulated transmission line of the angara-5-1 facility |
| |
Authors: | E. V. Grabovski A. N. Gribov A. A. Samokhin A. O. Shishlov |
| |
Affiliation: | 1. Troitsk Institute for Innovation and Fusion Research, Troitsk, Moscow, 142190, Russia
|
| |
Abstract: | One of the factors limiting the transmission of the electromagnetic pulse to the load in high-power electrophysical facilities is the current leakage in magnetically insulated transmission lines (MITLs). In this paper, the Angara-5-1 eight-module facility with an output power up to 6 TW is considered. The experimental and calculated time profiles of the leakage current for eight-module shots with a dynamic load (cylindrical arrays made of 40 tungsten wires) and single-module shots with a solid cylindrical metal load are compared. When interpreting the results, the contribution of vacuum electrons to the leakage current at the transition from the cylindrical to the conical section of the MITL is taken into account. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |