The pressure/volume relationship during dobutamine stress echocardiography in transplanted heart: comparison with quality of life and coronary anatomy
Authors:Giovanni Minardi  Giordano Zampi  Amedeo Pergolini  Giovanni Pulignano  Massimiliano Scappaticci  Francesca Moschella Orsini  Gaetano Pero  Paola Lilla Della Monica  Giovanni Cioffi  Francesco Musumeci
Institution:1. Department of Cardiovascular Science, Heart Transplant Center, “S. Camillo-Forlanini” Hospital, Circonvallazione Gianicolense, 87, Rome, 00151, Italy
2. Department of Cardiovascular Science, Catheterization Laboratory, “S. Camillo-Forlanini” Hospital, Rome, Italy
3. Department of Cardiology, Villa Bianca Hospital, Trento, Italy
Abstract:

Background

Cardiac allograft vasculopathy (CAV) is a major late complication in cardiac transplant recipients and has a relevant impact on outcome of these patients. Aims of this study: to compare, in cardiac transplant recipients patients, the diagnostic value of pressure/volume relationship (ESPVR) during dobutamine stress echocardiography (DSE) for coronary artery disease, assessed by Multislice Computed Tomography (MSCT), and by coronary angiography (CA). We also analyzed any possible relationship between ESPVR and the Health Related Quality of Life of the patients (HRQoL), evaluated by SF–36 questionnaire.

Methods

25 consecutive patients underwent DSE within 24 hours after MSCT coronary angiogram and then they underwent CA. The HRQoL questionnaire was administered to the patients in the settings of DSE. They were followed-up for 6 months.

Results

DSE has a sensitivity in detecting CAV of 67%, specificity of 95%, positive predictive value of 67% and negative predictive value of 95%; DSE with ESPVR has a sensitivity of 100%, specificity of 95%, positive predictive value of 75%, negative predictive value of 100%; MSCT has a sensitivity of 100%; specificity of 82%; positive predictive value of 43%; negative predictive value of 100%. Htx recipients with a flat-biphasic ESPVR, although asymptomatic, perceived a worst HRQoL compared with the up-sloping ESPVR population, and this is statistically significant for the general health (p 0.0004), the vitality (p 0.0013) and the mental health (p 0.021) SF-36 subscale.

Conclusions

Evaluation with DSE and ESPVR is accurate in the clinical control of heart transplant recipients reserving invasive evaluation only for patients with abnormal contractility indexes.