Measurement of anti-glomerular-basement-membrane antibodies by micro ELISA using insoluble antigens
Authors:Kay Barnard  M P James
Institution:(1) Department of Pathology, University of Bristol, University Walk, Bristol, UK;(2) Present address: Meat Research Institute, Langford, BS18 7DY Bristol, UK;(3) Present address: Whangarei Animal Health Laboratory, Ministry of Agriculture & Fisheries, Private Bag, Whangarei, New Zealand
Abstract:An enzyme immunoassay, using finely ground rabbit glomerular basement membrane (GBM) as an antigen, was able to detect sheep anti-rabbit GBM antibodies at serum dilutions of 1ratio32 000. The particulate GBM bound firmly to plastic micro ELISA plates without the aid of a linking agent, and the antigen-coated plates remained stable for several months when stored at –70°C. There were no appreciable differences between amino acid compositions of ground and whole GBM, and no detectable loss of antigens occurred during the grinding procedure. Competitive inhibition assays ,with collagenase and pepsin digests of rabbit GBM demonstrated preservation of collagenous and non-collagenous antigens in the ground GBM. The assay should prove to be a relatively simple and highly sensitive technique for detecting antibodies to a wide spectrum of GBM antigens.
Keywords:
本文献已被 SpringerLink 等数据库收录!