Comparison between blood hemoglobin concentration determined by point-of-care device and complete blood count in adult patients with dengue
Authors:Kantasit Wisanuvej  Kochawan Boonyawat  Chutchaiwat Savetamornkul  Sirapong Virapongsiri  Jatupon Krongvorakul  Somnuek Sungkanuparph  Angsana Phuphuakrat
Institution:1. Department of Medicine, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand ; 2. Chakri Naruebodindra Medical Institute, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Samut Prakan, Thailand ; 3. Department of Pathology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand ; George Washington University School of Medicine and Health Sciences, UNITED STATES
Abstract:BackgroundHematocrit measurement has been an indispensable tool for monitoring plasma leakage and bleeding in dengue patients. However, hematocrit measurement by automated methods is hampered by frequent venipunctures. Utility of point-of-care hemoglobin (POC-Hb) test for monitoring dengue patients has not been established. We evaluated the relationship between hemoglobin measured by POC-Hb testing and hematocrit measured by the automated method in adult dengue patients.Methodology and principal findingsAdult dengue patients were recruited at two university hospitals in Thailand from October 2019 to December 2020. POC-Hb test was performed using capillary blood simultaneously with venipuncture to obtain whole blood for an automated complete blood count (CBC) analysis. The correlation of hemoglobin and hematocrit measurement was evaluated. A total of 44 dengue patients were enrolled. Twenty-nine patients (65.9%) were female, with a median age of 31 years (interquartile range 22–41). Of the enrolled patients, 30 (68.2%), 11 (25.0%), and 3 (6.8%) were classified as dengue without warning signs, with warning signs, and severe dengue, respectively. Seven patients (15.9%) had hemoconcentration, and five patients (11.3%) had bleeding. A total of 216 pairs of POC-Hb and CBC were evaluated. A significant positive correlation was observed between hemoglobin measured by POC-Hb testing and hematocrit measured by an automated CBC (r = 0.869, p <0.001). Bland-Altman analysis between hemoglobin measured by POC-Hb testing and an automated CBC showed a bias of -0.43 (95% limit of agreement of -1.81 and 0.95). Using the cutoff of POC-Hb ≥20% as a criteria for hemoconcentration, the sensitivity and specificity of hemoconcentration detected by POC-Hb device were 71.4% and 100.0%, respectively.ConclusionsHemoglobin measurement by POC-Hb testing has a strong correlation with hematocrit in adult patients with dengue fever. However, the sensitivity in detecting hemoconcentration is fair. The adjunct use of capillary POC-Hb testing can decrease the frequency of venipuncture. Further study in children is encouraged.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号