Regional lung strain in dogs during deflation from total lung capacity
Authors:J R Rodarte  R D Hubmayr  D Stamenovic  B J Walters
Abstract:Regional lung distortion during deflation from total lung capacity to functional residual capacity (FRC) in intact supine and prone anesthetized dogs was determined from the displacement of multiple metallic markers embedded in the lung parenchyma. Distortion was expressed as strain (epsilon), which is related to fractional length changes. In the supine position, transverse strain (epsilon yy) was larger than vertical strain (epsilon xx) and cephalocaudal strain (epsilon zz) in the upper lobe. The FRC of the lower lobe was smaller than FRC of the upper lobe and all strains were larger, but epsilon zz increased most and became equal to epsilon yy. In the prone position, epsilon yy was largest in all upper lobes and in three of four lower lobes. Strains and volumes of the upper and lower lobes were similar. The upper and lower lobes rotated slightly around different axes, indicating that interpleural fissures allow additional degrees of freedom for the lungs to conform to the thoracic cavity. In the prone position, there were no consistent gradients of strain or volume. These results indicate that, in determining the regional distribution of FRC in the recumbent dog, in addition to the effect of gravity on the lung, there are important interactions between lung and thoracic cavity shapes.
Keywords:
本文献已被 PubMed 等数据库收录!