Intra-airway gas mixing during high-frequency ventilation
Authors:J Solway  N Gavriely  R D Kamm  J M Drazen  R H Ingram  M C Khoo  R Brown  A S Slutsky
Abstract:We examined the intra-airway gas transport mediated by high-frequency oscillations (HFO) in 10 nonintubated healthy volunteers using a method based on comparisons of single-breath N2-washout curves obtained after various durations of breath hold or high-frequency oscillations. With a mathematical analysis based on Fick's law of diffusion we computed the local transport parameter, effective diffusivity, during oscillations of frequency 2-24 Hz and tidal volume 10-120 ml and during breath hold alone. Local effective diffusivity increased with both oscillatory frequency and tidal volume at all levels in the tracheobronchial tree; the enhancing effect of tidal volume on local effective diffusivity was more pronounced than that of frequency so that effective diffusivity was greater with larger tidal volume at fixed frequency-tidal volume product (f . VT). The greatest enhancement of gas mixing within the lung during HFO (over breath hold) was seen in the central airways. In previous studies examining CO2 removal rate during HFO (J. Clin. Invest. 68: 1475, 1981), we found that CO2 output was also greater with larger tidal volume at fixed f . VT, and we attributed this to an end constraint imposed by a fresh gas bias flow. Results of the current study, performed without a bias flow, indicate that bias flow end constraint does not solely account for the observed dependence of CO2 output on frequency and tidal volume.