Very Preterm Infants Failing CPAP Show Signs of Fatigue Immediately after Birth
Authors:Melissa L Siew  Jeroen J van Vonderen  Stuart B Hooper  Arjan B te Pas
Institution:1. The Ritchie Centre, MIMR-PHI, Monash University, Clayton, Australia.; 2. Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, the Netherlands.; Hôpital Robert Debré, FRANCE,
Abstract:

Objective

To investigate the differences in breathing pattern and effort in infants at birth who failed or succeeded on continuous positive airway pressure (CPAP) during the first 48 hours after birth.

Methods

Respiratory function recordings of 32 preterm infants were reviewed of which 15 infants with a gestational age of 28.6 (0.7) weeks failed CPAP and 17 infants with a GA of 30.1 (0.4) weeks did not fail CPAP. Frequency, duration and tidal volumes (VT) of expiratory holds (EHs), peak inspiratory flows, CPAP-level and FiO2-levels were analysed.

Results

EH incidence increased <6 minutes after birth and remained stable thereafter. EH peak inspiratory flows and VT were similar between CPAP-fail and CPAP-success infants. At 9-12 minutes, CPAP-fail infants more frequently used smaller VTs, 0-9 ml/kg and required higher peak inspiratory flows. However, CPAP-success infants often used large VTs (>9 ml/kg) with higher peak inspiratory flows than CPAP-fail infants (71.8 ± 15.8 vs. 15.5 ± 5.2 ml/kg.s, p <0.05). CPAP-fail infants required higher FiO2 (0.31 ± 0.03 vs. 0.21 ± 0.01), higher CPAP pressures (6.62 ± 0.3 vs. 5.67 ± 0.26 cmH2O) and more positive pressure-delivered breaths (45 ± 12 vs. 19 ± 9%) (p <0.05)

Conclusion

At 9-12 minutes after birth, CPAP-fail infants more commonly used lower VTs and required higher peak inspiratory flow rates while receiving greater respiratory support. VT was less variable and larger VT was infrequently used reflecting early signs of fatigue.