Quantitation of N-ethyl-3,4-methylenedioxyamphetamine and its major metabolites in human plasma by high-performance liquid chromatography and fluorescence detection |
| |
Authors: | Michael Brunnenberg Hiltrud Lindenblatt Euphrosyne Gouzoulis-Mayfrank Karl-Artur Kovar |
| |
Abstract: | A HPLC method has been developed for the analogue of Ecstasy MDE and its major metabolites N-ethyl-4-hydroxy-3-methoxyamphetamine (HME) and 3,4-methylenedioxyamphetamine (MDA) in human plasma. In the course of our investigations we found that the methylenedioxyamphetamines and HME exhibit fluorescence at 322 nm. Therefore the detection could be carried out with a fluorescence (FL) detector. Solid-phase extraction was used for sample preparation and yielded high recovery rates greater than 95%. The limit of quantitation for MDE and its metabolites in the extracts was between 1.5 and 8.9 ng/ml and the method standard deviations were less than 5%. This sensitive, rapid and reliable analytical method has been used successfully in the quantitation of the substances in plasma samples obtained from 14 volunteers in two clinical studies after p.o. administration of 100 to 140 mg MDE*HCl. The maximum plasma concentrations were 235–465 ng/ml (MDE), 67–673 ng/ml (HME) and 7–33 ng/ml (MDA), respectively. Pharmacokinetic parameters have been investigated using the plasma concentration curves. |
| |
Keywords: | N-Ethyl-3 4-methylenedioxyamphetamine Ecstasy Plasma |
本文献已被 ScienceDirect 等数据库收录! |