Image analysis combined with quantitative cytochemistry
Authors:J S Ploem  A M J van Driel-Kulker  L Goyarts-Veldstra  J J Ploem-Zaaijer  N P Verwoerd  M van der Zwan
Institution:(1) Department of Histochemistry and Cytochemistry, Sylvius Laboratories, Wassenaarseweg 72, NL-2333 AL Leiden, The Netherlands
Abstract:Summary This paper describes the application of image analysis combined with a quantitative staining method for the analysis of cervical specimens. The image analysis is carried out with the Leyden Television Analysis System, LEYTAS, of which two versions are described. LEYTAS-1 as well as LEYTAS-2 have both been designed with a high degree of flexibility and interaction facilities. A much wider range of image analysis programs is however, possible with LEYTAS-2, enabling many applications. LEYTAS-1, the earlier version, consists of a Leitz microscope with automated functions, a TV camera, the Texture Analysis System (TAS, Leitz), a four-bit grey value memory and a minicomputer (PDP 11/23). Using this instrumentation 1,500 cervical smears prepared from cell suspensions and stained with acriflavin-Feulgen-Sits have been analysed in a completely automated procedure. Image transformations working in parallel on entire fields, have been used for cell selection and artefact rejection. Resulting alarms, consisting of selected single cells and non-rejected artefacts are stored in the grey value memory, which is displayed on a TV monitor. This option allows visual interaction after the machine diagnosis has been made. The machine diagnosis was correct in 320 out 321 specimens with a severe dysplasia or more serious lesion. The false positive rate in 561 morphologically negative specimens (normal and inflammation) was 16% (machine diagnosis). Visual interaction by subtracting the visually recognized false alarms from the total number of alarms reduces the false positive rate to 11%. In LEYTAS-2, which is based on LEYTAS-1 studies, the microscope is equipped with a new type of objective, enabling the analysis of microscope fields, which are four times as large as in LEYTAS-1. The image analysis part consists of the Modular Image Analysis Computer (MIAC, Leitz) and for alarm storage an eight-bit grey value processor is used. Comparison with LEYTAS-1 shows that cell selection capacities are similar and that the speed is four times higher.In honour of Prof. P. van Duijn
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号