Low-Dose Prospectively Electrocardiogram-Gated Axial Dual-Source CT Angiography in Patients with Pulsatile Bilateral Bidirectional Glenn Shunt: An Alternative Noninvasive Method for Postoperative Morphological Estimation
Authors:Xiaopeng Ji  Bin Zhao  Zhaoping Cheng  Biao Si  Zhiheng Wang  Yanhua Duan  Pei Nie  Haiou Li  Shifeng Yang  Hui Jiao  Ximing Wang
Institution:1. Shandong Medical Imaging Research Institute, Shandong University, Jinan, People''s Republic of China.; 2. Cardiovascular Institute of Jinan Military district, Jinan, People''s Republic of China.; University of Groningen, Netherlands,
Abstract:

Objective

To explore the clinical value of low-dose prospectively electrocardiogram-gated axial dual-source CT angiography (low-dose PGA scanning, CTA) in patients with pulsatile bilateral bidirectional Glenn shunt (bBDG) as an alternative noninvasive method for postoperative morphological estimation.

Methods

Twenty patients with pulsatile bBDG (mean age 4.2±1.6 years) underwent both low-dose PGA scanning and conventional cardiac angiography (CCA) for the morphological changes. The morphological evaluation included the anatomy of superior vena cava (SVC) and pulmonary artery (PA), the anastomotic location, thrombosis, aorto-pulmonary collateral circulation, pulmonary arteriovenous malformations, etc. Objective and subjective image quality was assessed. Bland–Altman analysis and linear regression analyses were used to evaluate the correlation on measurements between CTA and CCA. Effective radiation dose of both modalities was calculated.

Results

The CT attenuation value of bilateral SVC and PA was higher than 300 HU. The average subjective image quality score was 4.05±0.69. The morphology of bilateral SVC and PA was displayed completely and intuitively by CTA images. There were 24 SVC above PA and 15 SVC beside PA. Thrombosis was found in 1 patient. Collateral vessels were detected in 13 patients. No pulmonary arteriovenous malformation was found in our study. A strong correlation (R2>0.8, P<0.001) was observed between the measurements on CTA images and on CCA images. Bland–Altman analysis demonstrated a systematic overestimation of the measurements by CTA (the mean value of bias>0).The mean effective dose of CTA and CCA was 0.50±0.17 mSv and 4.85±1.34 mSv respectively.

Conclusion

CT angiography with a low-dose PGA scanning is an accurate and reliable noninvasive examination in the assessment of morphological changes in patients with pulsatile bBDG.