首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Simultaneous determination of benazepril hydrochloride and benazeprilat in plasma by high-performance liquid chromatography/electrospray-mass spectrometry
Authors:Xiao Weitao  Chen Bo  Yao Shouzhuo  Cheng Zeneng
Institution:Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Hunan Normal University), Ministry of Education, Hunan Normal University, Changsha 410081, PR China.
Abstract:An analytical method for simultaneous determination of benazepril and its active metabolite, benazeprilat, in human plasma by high-performance liquid chromatography/electrospray-mass spectrometry was developed and validated. Rutaecarpine was selected as the internal standard. The separation was achieved on a C(18) column with acetonitrile and aqueous solution (0.1% formic acid) as mobile phase with a gradient mode. The quantification of target compounds was using a selective ionization recording at m/z 425.5 for benazepril, m/z 397.5 for benzeprilat and m/z 288.3 for rutaecarpine. The correlation coefficients of the calibration curves were better than 0.992 (n = 6), in the range of 6.67-666.67 ng/ml for benazepril and benazeprilat. The inter- and intra-day accuracy, precision, linear range had been investigated in detail. The method can be used to assess the bioavailability and pharmacokinetics of the drug.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏