Hydrodynamics and mixing in down flow jet loop bioreactor with a non-Newtonian fluid |
| |
Authors: | Mr. M. Velan Dr. T. K. Ramanujam |
| |
Affiliation: | (1) Department of Chemical Engg., Indian Institute of Technology, 600 036 Madras, India |
| |
Abstract: | Gas holdup and liquid circulation time were measured in a down flow jet loop bioreactor with a non-Newtonian fluid. It was observed that the circulation time decreases with increase in nozzle diameter, draft tube to column diameter ratio and shear thinning of the media. The gas holdup increases with increase in gas and liquid velocities. The optimum draft tube to column diameter ratio was found to be 0.438. Correlations for gas holdup and circulation time involving operational and geometrical variables were presented. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |