首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Comparison of stress distribution in dental crown with different cusp angles: 3D finite element analysis
Authors:Han-Wool Kim  Byung-Ho Choi
Institution:1. Department of Mechanical Engineering, Dongguk University, Seoul, South Korea;2. Department of Dentistry Wonju College of Medicine, Yonsei University, Wonju, South Korea
Abstract:The purpose of this study is to measure the failure risk of a crown depending on the cusp angle. Three all-ceramic crown models consisting of CH (high incline), CM (middle incline), and CL (low incline) are designed. Stress is applied to the crown with Loading case-1 (top of cusp tip) and Loading case-2 (middle of cusp ridge) with the use of FEA software. In Loading case-1 and case-2, the CH showed the highest Maximum Principal Stress (MPS) while the CL showed the lowest MPS. The cusp angle is an influential factor affecting stress distribution in dental crowns.
Keywords:Finite element  tooth crown  stress distribution  cusp angle
设为首页 | 免责声明 | 关于勤云 | 加入收藏