High-power electromagnetic wave in a magnetically insulated transmission line of the ANGARA-5-1 facility |
| |
Authors: | A. A. Samokhin |
| |
Affiliation: | 1.Troitsk Institute for Innovation and Fusion Research,Troitsk, Moscow oblast,Russia |
| |
Abstract: | Studies of physical phenomena in magnetically insulated transmission lines (MITLs) of high-power pulsed current generators, analysis of operation of existing megavolt generators, and designing of new high-current generators with a power of up to ∼10 TW require creating an efficient numerical code for modeling the propagation of a high-power electromagnetic pulse in an MITL. This paper presents basic theoretical concepts of MITL operation in the framework of telegraph equations with allowance for electron leakage and variations in the electrode emissivity and analyzes propagation of an electromagnetic wave in the MITLs of the ANGARA-5-1 eight-module facility toward a dynamic load installed in the central unit with a matrix inductance. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|