Evaluation of different techniques for pregnancy diagnosis in sheep |
| |
Authors: | B.A. Ganaie M.Z. Khan R. Islam D.M. Makhdoomi S. Qureshi G.M. Wani |
| |
Affiliation: | aDivision of Animal Reproduction, Gynaecology and Obstetrics Faculty of Veterinary Sciences and Animal Husbandry, S. K. University of Agricultural Sciences and Technology (K), Shuhama, Alusteng, Srinagar-190006, Kashmir, India;bDivision of Veterinary Surgery and Radiology, SKUAST-K, Srinagar-190006, India;cDivision of Veterinary Microbiology and Immunology, SKUAST-K, Srinagar-190006, India |
| |
Abstract: | Fifty Corriedale ewes were used in this study to evaluate pregnancy diagnosis in sheep. Ewes were bred under a pen mating system and pregnancy diagnosis was initiated from day 15 post-mating, applying the diagnostic techniques of trans-abdominal real-time B-mode ultrasonography, Preg-alert (A-mode ultrasonography), the Doppler ultrasonic fetal pulse detector or the plasma progesterone concentration assay (EIA). These tests were repeated fortnightly on all the ewes until the onset of lambing. The accuracy of trans-abdominal real-time B-mode ultrasonography (68%) at days 15–30 of pregnancy increased to 100% by days 61–75 and remained constant until lambing. The accuracy of the Preg-alert (56%) diagnosis at days 31–45 increased to 94% by days 91–105 of gestation and then decreased to 82% from days 136 of gestation to lambing. The accuracy of both the Doppler ultrasound (56%) at days 31–45 and plasma progesterone assay (98%) at days 15–30 of gestation increased to 100% at days 76–90 and 46–60 of gestation, respectively and remained constant until parturition. The mean plasma progesterone concentration at days 0–6 (1.41 ± 0.21 ng/ml) increased to 4.0 ± 0.87 ng/ml at days 16–30 (days 18.23 ± 0.78) post-mating. Animals returning to estrus recorded less than 1 ng/ml at days 18.23 ± 0.78 post-mating. The accuracy of both the B-mode ultrasonic technique (78%) and plasma progesterone assay (98%) was significantly higher (P < 0.05) than the accuracy obtained with the A-mode and Doppler ultrasound (both 56%) at days 31–45 of gestation. The study concluded that real-time B-mode ultrasonography is the earliest, most accurate, safest, fastest and most economical method of pregnancy diagnosis in sheep at farm level. The A-mode and Doppler methods can also be used under field conditions, where sophisticated laboratory facilities are not available. Plasma progesterone assays (EIA) can be used as a means of early pregnancy diagnosis in organized sheep farms with fair accuracy. |
| |
Keywords: | Pregnancy diagnosis Sheep Ultrasonography Preg-alert Doppler ultrasonic equipment Progesterone assay |
本文献已被 ScienceDirect 等数据库收录! |
|