首页 | 本学科首页   官方微博 | 高级检索  
     


Elevated C-Reactive Protein Levels and Enhanced High Frequency Vasomotion in Patients with Ischemic Heart Disease during Brachial Flow-Mediated Dilation
Authors:Shogo Watanabe  Eisuke Amiya  Masafumi Watanabe  Munenori Takata  Atsuko Ozeki  Aya Watanabe  Shuichi Kawarasaki  Tomoko Nakao  Yumiko Hosoya  Kohzo Nagata  Ryozo Nagai  Issei Komuro
Affiliation:1. Department of Cardiovascular Medicine, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.; 2. Department of Pathophysiological Laboratory Sciences, Nagoya University Graduate School of Medicine, Aichi, Japan.; 3. Jichi Medical School, Tochigi, Japan.; National University of Singapore, Singapore,
Abstract:

Purpose

The physiological role of vasomotion, rhythmic oscillations in vascular tone or diameter, and its underlying mechanisms are unknown. We investigated the characteristics of brachial artery vasomotion in patients with ischemic heart disease (IHD).

Methods

We performed a retrospective study of 37 patients with IHD. Endothelial function was assessed using flow-mediated dilation (FMD), and power spectral analysis of brachial artery diameter oscillations during FMD was performed. Frequency-domain components were calculated by integrating the power spectrums in three frequency bands (in ms2) using the MemCalc (GMS, Tokyo, Japan): very-low frequency (VLF), 0.003–0.04 Hz; low frequency (LF), 0.04–0.15 Hz; and high frequency (HF), 0.15–0.4 Hz. Total spectral power (TP) was calculated as the sum of all frequency bands, and each spectral component was normalized against TP.

Results

Data revealed that HF/TP closely correlated with FMD (r = −0.33, p = 0.04), whereas VLF/TP and LF/TP did not. We also explored the relationship between elevated C-reactive protein (CRP) levels and vasomotion. HF/TP was significantly increased in subjects with high CRP levels (CRP;>0.08 mg/dL) compared with subjects with low CRP levels (0.052±0.026 versus 0.035±0.022, p<0.05). The HF/TP value closely correlated with CRP (r = 0.24, p = 0.04), whereas the value of FMD did not (r = 0.023, p = 0.84). In addition, elevated CRP levels significantly increased the value of HF/TP after adjustment for FMD and blood pressure (β = 0.33, p<0.05).

Conclusion

The HF component of brachial artery diameter oscillation during FMD measurement correlated well with FMD and increased in the presence of elevated CRP levels in subjects with IHD.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号