Rapid concentration of bacteria using submicron magnetic anion exchangers for improving PCR-based multiplex pathogen detection |
| |
Authors: | Yang Kun Jenkins Daniel M Su Wei Wen |
| |
Institution: | Department of Molecular Biosciences & Bioengineering, University of Hawaii, 1955 East-West Road, Ag. Sci. 218, Honolulu, HI 96822, United States |
| |
Abstract: | Rapid concentration of bacterial targets from dilute solutions to improve subsequent PCR detection is investigated in this study. Submicron (average size 500 nm) superparamagnetic anion-exchangers (SiMAG-DEAE) were used successfully to concentrate target bacteria from very dilute solutions. A mass-balance model predicted that for Escherichia coli, the extent of cell concentrating increases almost linearly with increasing sample/SiMAG volume ratio up to about 2000, accompanied by only a slight decrease in the capture efficiency (< 10%). Our experimental data generally support this analysis in that the SiMAG beads concentrated bacterial targets by two to three orders of magnitude using a sample/bead volume ratio of about 1000, and lowered the PCR detection limit to a level of 102 CFU/mL, from 104 to 105 CFU/mL without concentrating. Several target bacteria can be concentrated concurrently and detected via multiplex PCR, as illustrated using E. coli and Agrobacterium tumefaciens as model bacteria. Finally, concentration and detection of bacteria in fresh produce samples were demonstrated. The integration of submicron magnetic ion exchangers and PCR detection provides an appealing alternative to immunomagnetic separation/PCR in improving pathogen detection. |
| |
Keywords: | Bacteria concentration Ion exchange Magnetic separation Pathogen detection Sample preparation Nucleic acid amplification |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|