首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Analysis of Neurotrophin/Receptor Interactions with a gD-Flag-Modified Quantitative Kinase Receptor Activation (gD.KIRA) Enzyme-Linked Immunosorbent Assay
Authors:Michael D Sadick  Amy Galloway  David Shelton  Victoria Hale  Suzanne Weck  Vince Anicetti  Wai Lee T Wong
Institution:aDepartment of BioAnalytical Technology, Genentech, Inc. South San Francisco, California, 94080;bDepartment of Neuroscience, Genentech, Inc. South San Francisco, California, 94080;cDepartment of Pharmacokinetics, Genentech, Inc. South San Francisco, California, 94080;dDepartment of Formulation Design, Genentech, Inc. South San Francisco, California, 94080;eDepartment of Quality Control, Genentech, Inc. South San Francisco, California, 94080
Abstract:A rapid, sensitive, and high-capacity assay has been developed to quantify ligand-induced receptor tyrosine kinase activation in terms of receptor phosphorylation. The assay, termed a “kinase receptor activation” or KIRA-ELISA, utilizes two separate microtiter plates, one for cell culture and ligand stimulation, and the other for receptor capture and phosphotyrosine ELISA. The assay was developed for analysis of neurotrophin-induced trkA, trkB, or trkC activation. It utilizes a trkA, trkB, or trkC receptor fused with a 26-amino-acid polypeptide flag derived from HSV glycoprotein D (gD.trkA, B, or C, respectively) on the amino-terminus, stably transfected into CHO cells. Stimulated receptors were solubilized with Triton X-100 buffer and then captured in ELISA wells coated with gD-specific mAb. The degree of receptor autophosphorylation was quantified by anti-phosphotyrosine ELISA. Reproducible standard curves were generated with an EC50of approximately 16 ng/ml NGF for gD.trkA KIRA, 11 ng/ml for NT4/5 and 20 ng/ml for BDNF in gD.trkB KIRA, and 9.4 ng/ml for NT3 in gD.trkC KIRA. When the gD.trkA KIRA assay was used to quantify serum NGF or NT3 following administration to rats, the assay agreed well with currently existing ELISA assays. When the gD.trkA KIRA assay was used to test several NGF variants, as well as NGF stability samples, the capacity of the assay to quantify ligand bioactivity compared well with the more widely used radioreceptor binding and PC 12 cell survival assays. The gD.trk KIRA assays show great potential as rapid bioassays, capable of quantitative, consistent, and stability indicating analyses.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号