首页 | 本学科首页   官方微博 | 高级检索  
     


Improved Reversed Passive Hemagglutination for Simple and Rapid Detection of Staphylococcal Enterotoxins A~E in Food
Authors:Sumio Yamada  Hideo Igarashi  Takeshi Terayama
Abstract:Detection and identification of staphylococcal enterotoxins in food or culture filtrates were performed using the reversed passive hemagglutination (RPHA) technique, with formalized sheep red blood cells (FSRBC) sensitized with immunoglobulins of anti-A, B, C, D, and E rabbit hyperimmune sera fractionated by affinity chromatography. The FSRBC sensitized with anti-A~E immunoglobulins showed a high level of reactivity and specificity in RPHA, against homologous types of purified enterotoxins and culture filtrates of toxin-producing strains. No non-specific reactions with various ingredients in foods nor cross-reactions among enterotoxin types were observed. The minimum amount of enterotoxins in foods detected by RPHA was calculated to be 0.01 μg/g without concentration, and the recovery rate of experimentally added toxins was calculated to be about 80%. Under routine laboratory practice, detection and identification of enterotoxins from incriminated foods of five food poisoning outbreaks were performed by RPHA within 3 hr after reception of the specimens. Among them, three were determined to be enterotoxin A food poisoning, one to be toxin C and the rest to be intoxication of A and D. The concentration of the toxins was between 0.014 and 3.65 μg per gram of food.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号