首页 | 本学科首页   官方微博 | 高级检索  
   检索      


A novel phantom with dia- and paramagnetic substructure for quantitative susceptibility mapping and relaxometry
Institution:1. Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany;2. Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany;3. Faculty of Medicine, Heidelberg University, Heidelberg, Germany;1. Institute of Biostructures and Bioimaging, Italian National Research Council, Via T. De Amicis, 95, 80145 Napoli, Italy;2. Department of Advanced Biomedical Sciences, University of Napoli “Federico II”, 80131 Napoli, Italy;3. Department of Electrical Engineering and Information Technology, University of Napoli “Federico II”, 80125 Napoli, Italy;1. Radiology, University of Michigan, Ann Arbor, MI, United States;2. Modus Medical Devices Inc., London, ON, CA, Canada;3. Siemens Healthcare GmbH, Erlangen, DE, Germany;4. MR Clinical Science, Philips Healthcare, Best, NL, Netherlands;5. Radiology and Imaging, Hospital for Special Surgery, New York, NY, United States;1. Princess Margaret Cancer Centre, University Health Network, Department of Radiation Oncology, University of Toronto, 610 University Avenue, Toronto, Ontario M5G 2M9, Canada;2. Modus QA, London, Ontario N6H 5L6, Canada;3. Cross Cancer Institute, Alberta Health Services, Department of Radiation Oncology, University of Alberta, 11560 University Avenue, Edmonton, AB T6G 1Z2, Canada;1. Department of Radiology, University of Calgary, Calgary, Alberta, Canada;2. Department of Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada;3. Department of Hotchkiss Brain Institute, University of Calgary, Calgary, Alberta, Canada;4. Department of Biomedical Engineering, McGill University, Montreal, Quebec, Canada;1. Department of Radiology, German Cancer Research Center, Im Neuenheimer Feld 220, 69120 Heidelberg, Germany;2. Medical Faculty, Ruprecht-Karls-University Heidelberg, Heidelberg, Germany
Abstract:
Keywords:Quantitative susceptibility mapping phantom  Magnetic susceptibility  Relaxation rate  Susceptibility source separation  Substructure  QSM"}  {"#name":"keyword"  "$":{"id":"k0010"}  "$$":[{"#name":"text"  "_":"quantitative susceptibility mapping  VOI"}  {"#name":"keyword"  "$":{"id":"k0020"}  "$$":[{"#name":"text"  "_":"volume of interest  calcium carbonate  WC"}  {"#name":"keyword"  "$":{"id":"k0040"}  "$$":[{"#name":"text"  "_":"tungsten carbide
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号