首页 | 本学科首页   官方微博 | 高级检索  
     


Potential of antibody test using Schistosoma mansoni recombinant serpin and RP26 to detect light-intensity infections in endemic areas
Affiliation:1. Instituto de Investigaciones Biomédicas “Dr. Francisco J. Triana Alonso” (BIOMED) and Departamento de Parasitología, Facultad de Ciencias de la Salud, Universidad de Carabobo, Sede Aragua, Maracay, Venezuela;2. Center for Infectious Diseases Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, the Netherlands;3. Utrecht University, Faculty of Veterinary Medicine, Institute for Risk Assessment Sciences (IRAS), Utrecht, the Netherlands;4. Laboratorio de Investigaciones en Bilharzia, Departamento de Parasitología, Facultad de Ciencias de la Salud, Universidad de Carabobo, Carabobo, Sede Valencia, Venezuela
Abstract:Schistosomiasis remains a worldwide public health problem, especially in sub-Saharan Africa. The World Health Organization targets the goal for its elimination as a public health problem in the 2030 Neglected Tropical Diseases (NTDs) Roadmap. Concerted action and agile responses to challenges will be necessary to achieve the targets. Better diagnostic tests can accelerate progress towards the elimination by monitoring disease trends and evaluating the effectiveness of interventions; however, current examinations such as Kato–Katz technique are of limited power to detect light-intensity infections. The point-of-care circulating cathodic antigen (POC-CCA) test shows a higher sensitivity compared to the reference standard, Kato-Katz technique, but it still lacks sufficient sensitivity with low infection intensity. In this study, we examined antibody reactions against recombinant protein antigens; Schistosoma mansoni serine protease-inhibitor (SmSerpin) and RP26, by enzyme-linked immunosorbent assay (ELISA) in plasma samples with light-intensity infection. The sensitivity using the cocktail antigen of recombinant SmSerpin and RP26 showed 83.7%. The sensitivity using S. mansoni soluble egg antigen (SmSEA) was 90.8%, but it showed poor specificity (29.7%), while the cocktail antigen presented improved specificity (61.4%). We conclude that antibody detection to the SmSerpin and RP26 protein antigens is effective to detect S. mansoni light-intensity infections. Our study indicates the potential of detecting antibody against recombinant protein antigens to monitor the transmission of schistosomiasis in low endemicity contexts.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号