Measurement of subcutaneous tissue fluid pressure using a skin-cup method
Authors:Adair, T. H.   Guyton, A. C.
Abstract:We developed a new method for measuring tissue fluid pressure in subcutaneous tissue. Porous Teflon cylinders were permanently implanted subcutaneously into the inguinal area of 10 dogs, and after several weeks a skin concavity formed in the center of each of the cylinders. A small needle attached to a recording system was inserted into the free tissue fluid lining the concavity, and the tissue fluid pressure averaged -8.8 +/- 2.7 (SD) mmHg. Next, a hollow Plexiglas cup was placed over the concavity and glued to the skin. The air pressure in the skin cup was continually adjusted (using an electromechanical servo-control system) to pull the skin upward and to hold it perfectly flat across the upper ridge of the Teflon cylinder. The simultaneously recorded needle and cup pressures averaged -9.1 +/- 2.4 and -8.6 +/- 2.6 mmHg, respectively, during steady-state conditions with the skin in a flat position. Both pressures also responded appropriately to dynamic changes in tissue fluid pressure caused by increasing and decreasing the volume of the free tissue fluid. Because the skin was flat, the equivalences of pressures above and below the skin is consistent with the hypothesis that the skin was not tethered significantly to the underlying tissues and that cup pressure accurately estimates the tissue free fluid pressure.
Keywords: