首页 | 本学科首页   官方微博 | 高级检索  
     


Time-resolved fluoroimmunoassay of plasma and urine O-desmethylangolensin
Authors:L'homme Rafaëlla  Brouwers Elke  Al-Maharik Nawaf  Lapcík O  Hampl R  Mikola Heikki  Wähälä K  Adlercreutz Herman
Affiliation:

a Division of Clinical Chemistry and Institute for Preventive Medicine, Nutrition and Cancer, Folkhälsan Research Center, University of Helsinki, PB 60, FIN-00014, Helsinki, Finland

b Laboratory of Organic Chemistry, Department of Chemistry, P.O. Box 55, University of Helsinki, Fin-00014, Helsinki, Finland

c Department of Chemistry of Natural Substances, Institute of Chemistry, Technicka 5, 166 28, Praha 6, Czech Republic

d Institute of Endocrinology, 116 94, Praha 1, Czech Republic

e Wallac Oy P.O. Box 10, FIN-20101, Turku, Finland

Abstract:We present a method for the determination of the phytoestrogen metabolite O-desmethylangolensin (O-DMA) in plasma (serum) and in urine. O-DMA is a metabolite of daidzein, which occurs in soybeans. It has been suggested that isoflavones may afford protection against breast and prostate cancer and therefore, also the metabolites are of interest. The method is based on time-resolved fluoroimmunoassay (TR–FIA) using a europium chelate as a label. After the synthesis of 4′′-O-carboxymethyl-O-DMA, this compound is coupled to bovine serum albumin, and then used as antigen in immunization of rabbits. The tracers with the europium chelate are synthesized using the same 4′′-O-derivative of the -methyldeoxybenzoin. After enzymatic hydrolysis and ether extraction the immunoassay is carried out by time resolved fluoroimmunoassay (TR–FIA). Cross-reactivity was tested with angolensin, dihydrogenistein, dihydrodaidzein, equol, 6′-OH-angolensin, trans-4-OH-equol, 6′-OH-O-DMA, cis-4-OH-equol and 5-OH-equol. The antiserum cross-reacted only with angolensin. This cross-reactivity seems not to influence the results, which were highly specific. Plasma samples are hydrolyzed and extracted. Urine samples are analyzed directly after hydrolysis without extraction. The correlation coefficient between the plasma TR–FIA results and the GC–MS results was high; r value was 0.985. The correlation coefficient between the urine TR–FIA results and the GC–MS results was high over the entire range of concentrations (0–1500 nmol/l); r value was 0.976, but lower in the low concentration range (0–100 nmol/l), i.e. value was 0.631. The intra-assay coefficients of variation (CVs) for plasma O-DMA concentrations and for urine O-DMA concentrations at three different concentrations varied 2.8–7.7 and 3.0–6.0%, respectively and the inter-assay CVs varied 3.8–8.9 and 4.4–6.6%, respectively. The working range of the plasma and urine O-DMA assays was 0.5–512 nmol/l.
Keywords:Immunoassay   Phytoestrogens   Isoflavones   Urine   O-desmethylangolensin   Fluorometry
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号