Improved high-performance liquid chromatography determination of methotrexate and its major metabolite in plasma using a poly(styrene-divinylbenzene) column |
| |
Affiliation: | 1. Allergy and Clinical Immunology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA;2. Department of Chemistry, Portland State University, Portland, OR 97207, USA;1. Clinical Microbiology and Infectious Diseases Department, Hospital General Universitario Gregorio Marañón, Doctor Esquerdo 46, 28007 Madrid, Spain;2. Instituto de Investigación Sanitaria, Hospital Gregorio Marañón, Doctor Esquerdo 46, 28007 Madrid, Spain;3. Department of Medicine, School of Medicine, Universidad Complutense de Madrid, Avda. Complutense s/n, 28040 Madrid, Spain;4. Laboratory of Reference and Research on Mycology, National Center for Microbiology, Instituto de Salud Carlos III, Carretera de Majadahonda-Pozuelo Km. 2.200, 28220 Majadahonda, Spain;5. Advanced Imaging Unit, Centro Nacional de Investigaciones Cardiovasculares Carlos III (CNIC), Melchor Fernández Almagro 3, 28029 Madrid, Spain;6. CIBER Enfermedades Respiratorias-CIBERES (CB06/06/0058), Doctor Esquerdo 46, 28007 Madrid, Spain |
| |
Abstract: | A sensitive high-performance liquid chromatographic assay has been developed for measuring plasma concentrations of methotrexate and its major metabolite, 7-hydroxymethotrexate. Methotrexate and metabolite were extracted from plasma using solid-phase extraction. An internal standard, aminopterin was used. Chromatographic separation was achieved using a 15-cm poly(styrene-divinylbenzene) (PRP-1®) column. This column is more robust than a silica-based stationary phase. Post column, the eluent was irradiated with UV light, producing fluorescent photolytic degradation products of methotrexate and the metabolite. The excitation and emission wavelengths of fluorescence detection were at 350 and 435 nm, respectively. The mobile phase consisted of 0.1 M phosphate buffer (pH 6.5), with 6% N,N-dimethylformamide and 0.2% of 30% hydrogen peroxide. The absolute recoveries for methotrexate and 7-hydroxymethotrexate were greater than 86%. Precision, expressed as a coefficient of variation (n=6), was <10% at each of five methotrexate concentrations in the range 2.5–50 ng/ml. The limits of quantitation of methotrexate were 1 and 2.5 ng/ml for methotrexate and 7-hydroxymethotrexate, respectively (using 1 ml plasma). A robust HPLC method has been developed for the reproducible quantitation of methotrexate in plasma of patients taking a weekly dose of methotrexate for rheumatoid arthritis. |
| |
Keywords: | |
本文献已被 ScienceDirect 等数据库收录! |
|