首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Perfusion flow rate substantially contributes to the performance of the HepaRG‐AMC‐bioartificial liver
Authors:Geert AA Nibourg  Justin D Boer  Tessa V van der Hoeven  Mariëtte T Ackermans  Thomas M van Gulik  Robert AFM Chamuleau  Ruurdtje Hoekstra
Institution:1. Department of Surgery (Surgical Laboratory), Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands;2. telephone: 31‐20‐5666683;3. fax: 31‐20‐6976621;4. Tytgat Institute for Liver and Intestinal Research, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands;5. Department of Clinical Chemistry, Laboratory of Endocrinology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
Abstract:Bioartificial livers (BALs) are bioreactors containing liver cells that provide extracorporeal liver support to liver‐failure patients. Theoretically, the plasma perfusion flow rate through a BAL is an important determinant of its functionality. Low flow rates can limit functionality due to limited substrate availability, and high flow rates can induce cell damage. This hypothesis was tested by perfusing the AMC‐BAL loaded with the liver cell line HepaRG at four different medium flow rates (0.3, 1.5, 5, and 10 mL/min). Hepatic functions ammonia elimination, urea production, lactate consumption, and 6β‐hydroxylation of testosterone showed 2–20‐fold higher rates at 5 mL/min compared to 0.3 mL/min, while cell damage remained stable. However, at 10 mL/min cell damage was twofold higher, and maximal hepatic functionality was not changed, except for an increase in lactate elimination. On the other hand, only a low flow rate of 0.3 mL/min allowed for an accurate measurement of the ammonia and lactate mass balance across the bioreactor, which is useful for monitoring the BAL's condition during treatment. These results show that (1) the functionality of a BAL highly depends on the perfusion rate; (2) there is a universal optimal flow rate based on various function and cell damage parameters (5 mL/min for HepaRG‐BAL); and (3) in the current set‐up the mass balance of substrate, metabolite, or cell damage markers between in‐and out‐flow of the bioreactor can only be determined at a suboptimal, low, perfusion rate (0.3 mL/min for HepaRG‐BAL). Biotechnol. Bioeng. 2012; 109: 3182–3188. © 2012 Wiley Periodicals, Inc.
Keywords:bioartificial liver  flow rate  HepaRG  perfusion
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号