首页 | 本学科首页   官方微博 | 高级检索  
     


A survey of formal methods for determining the centre of rotation of ball joints
Authors:Ehrig Rainald M  Taylor William R  Duda Georg N  Heller Markus O
Affiliation:1. Research Laboratory, Center for Musculoskeletal Surgery, Charité – Universitätsmedizin Berlin, Augustenburger Platz 1, D-13353 Berlin, Germany;2. Zuse Institute Berlin (ZIB), Berlin, Germany;1. Institut de Biomécanique Humaine Georges Charpak, Arts et Métiers ParisTech, 151 boulevard de l''Hôpital, F-75013 Paris, France;2. Hugh Williamson Gait Analysis Laboratory, The Royal Children’s Hospital, 50 Flemington Road, Parkville Victoria, 3052 Melbourne, Australia;3. The Murdoch Children’s Research Institute, Melbourne, Australia;1. Gait Laboratory, Central Remedial Clinic, Clontarf, Dublin 3, Ireland;2. Trinity Centre for Bioengineering, Parsons Building, Trinity College Dublin, Dublin 2, Ireland
Abstract:The determination of an accurate centre of rotation (CoR) from segment marker positions is of interest across a wide range of applications, but particularly for clinical gait analysis and for estimating the hip joint centre during surgical intervention of the knee, for limb alignment purposes. For the first time in this survey of formal methods, we classify, analyse and compare different methods (geometric, algebraic, bias compensated algebraic, and Pratt sphere fit methods, as well as the centre transformation technique, the Holzreiter approach, the helical pivot technique, the Schwartz transformation techniques, the minimal amplitude point method and the Stoddart approach) for the determination of spherical joint centres from marker position data. In addition, we propose a new method, the symmetrical CoR estimation or SCoRE, in which the coordinates of the joint centre must only remain constant relative to each segment, thus not requiring the assumption that one segment should remain at rest. For each method, 1000 CoR estimations were analysed with the application of isotropic, independent and identically distributed Gaussian noise (standard deviation 0.1cm) to each of the marker positions, to all markers on the segment simultaneously and the two in combination. For the test conditions used here, most techniques were capable of determining the CoR to within 0.3 cm, as long as the spherical range of motion (RoM) of the joint was 45 degrees or more. Under the most stringent conditions tested, however, the SCoRE was capable of best determining the CoR, to within approximately 1.2mm with a RoM of 20 degrees . The correct selection and application of these methodologies should help improve the accuracy of surgical navigation and clinical kinematic measurement.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号