Authors:F.‐B. Frechen  W. Schier  M. Wett  A. Waldhoff
Abstract:In the future, upgrading of existing wastewater treatment plants (wwtps) will be more important than the erection of entirely new plants, as most of the plants necessary in Germany already exist. Thus far, membrane bioreactor (MBR) technology is not used as an alternative for plant upgrading in Germany. However, at several locations the preconditions indicate that the application of the MBR technology for upgrading of plants may be favorable. These preconditions include the need for a substantial enlargement of the aeration tank volume and/or the need to improve the efficiency of the final sedimentation tanks, and also require that the existing tanks be in a good state, so that the tanks can be used in the future. The relevant preconditions and the basic upgrading concept using the MBR technology were presented earlier. Depending on the local preconditions regarding the existing tank volume, a specific aspect of this application can be an operation mode using “non‐conventional low MLSS (mixed liquor suspended solids) concentrations” (5 kg MLSS/m3 through 7 kg MLSS/m3) due to the amount of the existing tank volume. Two research projects were carried out covering the operation of five pilot plants on a cubic meter scale to demonstrate the feasibility of this kind of MBR process. This paper presents the core results of this research work.