Long wavelength fluorophores and cell-by-cell correction for autofluorescence significantly improves the accuracy of flow cytometric energy transfer measurements on a dual-laser benchtop flow cytometer
Authors:Sebestyén Zsolt  Nagy Péter  Horváth Gábor  Vámosi György  Debets Reno  Gratama Jan W  Alexander Denis R  Szöllosi János
Affiliation:Department of Biophysics and Cell Biology, Faculty of Medicine, Medical and Health Science Center, University of Debrecen, Debrecen, Hungary.
Abstract:BACKGROUND: Flow cytometric fluorescence resonance energy transfer (FCET) is an efficient method to map associations between biomolecules because of its high sensitivity to changes in molecular distances in the range of 1-10 nm. However, the requirement for a dual-laser instrument and the need for a relatively high signal-to-noise system (i.e., high expression level of the molecules) pose limitations to a wide application of the method. METHODS: Antibodies conjugated to cyanines 3 and 5 (Cy3 and Cy5) were used to label membrane proteins on the cell surface. FCET measurements were made on a widely used benchtop dual-laser flow cytometer, the FACSCalibur, by using cell-by-cell analysis of energy transfer efficiency.ResultsTo increase the accuracy of FCET measurements, we applied a long wavelength donor-acceptor pair, Cy3 and Cy5, which beneficially affected the signal-to-noise ratio in comparison with the classic pair of fluorescein and rhodamine. A new algorithm for cell-by-cell correction of autofluorescence further improved the sensitivity of the technique; cell subpopulations with only slightly different FCET efficiencies could be identified. The new FCET technique was tested on various direct and indirect immunofluorescent labeling strategies. The highest FCET values could be measured when applying direct labeling on both (donor and acceptor) sides. Upon increasing the complexity of the labeling scheme by introducing secondary antibodies, we detected a decrease in the energy transfer efficiency. CONCLUSIONS: We developed a new FCET protocol by applying long wavelength excitation and detection of fluorescence and by refining autofluorescence correction. The increased accuracy of the new method makes cells with low receptor expression amenable to FCET investigation, and the new approach can be implemented easily on a commercially available dual-laser flow cytometer, such as a FACSCalibur.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号