首页 | 本学科首页   官方微博 | 高级检索  
     


Development and validation of a high-throughput method for the quantitative analysis of d-amphetamine in rat blood using liquid chromatography/MS on a hybrid triple quadrupole-linear ion trap mass spectrometer and its application to a pharmacokinetic study
Authors:Nicola Cesari  Stefano FontanaDino Montanari  Simone Braggio
Affiliation:Department of Neurosciences CEDD DMPK, GlaxoSmithKline Medicines Research Centre, Via Fleming 4, 37135 Verona, Italy
Abstract:Amphetamines are a group of sympathomimetic drugs that exhibit strong central nervous system stimulant effects. d-Amphetamine ((+)-alpha-methylphenetylamine) is the parent drug in this class to which all others are structurally related. In drug discovery, d-amphetamine is extensively used either for the exploration of novel mechanisms involving the catecholaminergic system, or for the validation of new behavioural animal models. Due to this extensive use of d-amphetamine in drug research and its interest in toxicologic–forensic investigation, a specific and high-throughput method, with minimal sample preparation, is necessary for routine analysis of d-amphetamine in biological samples. We propose here a sensitive, specific and high-throughput bioanalytical method for the quantitative determination of d-amphetamine in rat blood using MS3 scan mode on a hybrid triple quadrupole-linear ion trap mass spectrometer (LC–MS/MS/MS). Blood samples, following dilution with water, were prepared by fully automated protein precipitation with acetonitrile containing an internal standard. The chromatographic separation was achieved on a Waters XTerra C18 column (2.1 mm × 30 mm, 3.5 μm) using gradient elution at a flow rate of 1.0 mL/min over a 2 min run time. An Applied Biosystems API4000 QTRAP™ mass spectrometer equipped with turbo ion-spray ionization source was operated simultaneously in MS3 scan mode for the d-amphetamine and in multiple reaction monitoring (MRM) for the internal standard. The MS/MS/MS ion transition monitored was m/z 136.1 → 119.1 → 91.1 for the quantitation of d-amphetamine and for the internal standard (rolipram) the MS/MS ion transition monitored was m/z 276.1 → 208.2. The linear dynamic range was established over the concentration range 0.5–1000 ng/mL (r2 = 0.9991). The method was rugged and sensitive with a lower limit of quantification (LLOQ) of 0.5 ng/mL. All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. This method was successfully applied to evaluate the pharmacokinetics of d-amphetamine in rat. On a more general extent, this work demonstrated that the selectivity of the fragmentation pathway (MS3) can be used as alternative approach to significantly improve detection capability in complex situation (e.g., small molecules in complex matrices) rather than increasing time for sample preparation and chromatographic separation.
Keywords:Protein precipitation   d-Amphetamine   LC&ndash  MS/MS/MS   Pharmacokinetics
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号