首页 | 本学科首页   官方微博 | 高级检索  
     


A sensitive and selective liquid chromatography/tandem mass spectrometry method for determination of MLN8237 in human plasma
Authors:Emily Lipsitz  Ganesh Moorthy  Yael Mosse  Elizabeth Fox  Peter C. Adamson
Affiliation:1. Division of Clinical Pharmacology and Therapeutics, The Children''s Hospital of Philadelphia, United States;2. Division of Oncology, The Children''s Hospital of Philadelphia, United States
Abstract:We describe a selective and a highly sensitive high-performance liquid chromatography–electron spray ionization-collision induced dissociation-tandem mass spectrometry (HPLC–ESI-CID-MS/MS) assay for the Aurora A kinase inhibitor MLN8237 in human plasma. The intra-day precision based on the standard deviation of replicates of quality control samples ranged from 0.2 to 4% and with accuracy ranging from 96 to 102%. The inter-day precision ranged from 0.5 to 7% and the accuracy ranged from 93 to 105%. Stability studies showed that MLN8237 was stable both during the expected conditions for sample preparation and storage. The lower limit of quantification for MLN8237 was 5 ng/mL. The analytical method showed excellent sensitivity, precision, and accuracy. This method is robust and is being successfully employed in a Children's Oncology Group Phase 1 Consortium study of MLN8237 in children with cancer.
Keywords:MLN8237   LC&ndash  ESI-CID-MS/MS   Plasma   Pediatric   Cancer
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏