Indole-3-acetic Acid Levels of Plant Tissue as Determined by a New High Performance Liquid Chromatographic Method |
| |
Authors: | Sweetser P B Swartzfager D G |
| |
Affiliation: | E. I. du Pont de Nemours and Company, Central Research and Development Department, Experimental Station, Wilmington, Delaware 19898. |
| |
Abstract: | A method for the analysis of indole-3-acetic acid (IAA) in plant extracts has been developed based on high performance liquid chromatography separation of IAA on a microparticulate strong anion exchange column followed by quantitation with two selective detectors: an electrochemical, carbon paste amperometric detector and/or a fluorescence detector. The detection limit for IAA is less than 1 nanogram with the fluorescence detector and less than 50 picograms with the electrochemical detector. The IAA levels are reported for various tissues of wheat, pinto beans, soybeans, cotton, and corn. |
| |