Gamma-index method sensitivity for gauging plan delivery accuracy of volumetric modulated arc therapy |
| |
Affiliation: | 1. Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Seoul National University Graduates School of Convergence Science and Technology, Seoul, Republic of Korea;2. Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea;3. Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea;4. Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea;5. Center for Convergence Research on Robotics, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea;6. Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul, Republic of Korea |
| |
Abstract: | PurposeThe aim of this study was to investigate the sensitivity of the gamma-index method according to various gamma criteria for volumetric modulated arc therapy (VMAT).MethodsTwenty head and neck (HN) and twenty prostate VMAT plans were retrospectively selected for this study. Both global and local 2D gamma evaluations were performed with criteria of 3%/3 mm, 2%/2 mm, 1%/2 mm and 2%/1 mm. In this study, the global and local gamma-index calculated the differences in doses relative to the maximum dose and the dose at the current measurement point, respectively. Using log files acquired during delivery, the differences in parameters at every control point between the VMAT plans and the log files were acquired. The differences in dose–volumetric parameters between reconstructed VMAT plans using the log files and the original VMAT plans were calculated. The Spearman's rank correlation coefficients (rs) were calculated between the passing rates and those differences.ResultsConsiderable correlations with statistical significances were observed between global 1%/2 mm, local 1%/2 mm and local 2%/1 mm and the MLC position differences (rs = −0.712, −0.628 and −0.581). The numbers of rs values with statistical significance between the passing rates and the changes in dose–volumetric parameters were largest in global 2%/2 mm (n = 16), global 2%/1 mm (n = 15) and local 2%/1 mm (n = 13) criteria.ConclusionLocal gamma-index method with 2%/1 mm generally showed higher sensitivity to detect deviations between a VMAT plan and the delivery of the VMAT plan. |
| |
Keywords: | |
本文献已被 ScienceDirect 等数据库收录! |
|