首页 | 本学科首页   官方微博 | 高级检索  
     


The optimal tomotherapy treatment planning parameters for extremity soft tissue sarcomas
Affiliation:1. Medical Physics, San Raffaele Scientific Institute, Milano, Italy;2. Radiotherapy, San Raffaele Scientific Institute, Milano, Italy;3. Radiotherapy Department, Candiolo Cancer Institute – FPO, IRCCS, Italy;4. Department of Radiotherapy, Regina Elena National Cancer Institute, Rome, Italy;5. Radiation Oncology 1, Fondazione IRCCS Istituto Nazionale Tumori, Milano, Italy;6. Prostate Cancer Program, Fondazione IRCCS Istituto Nazionale Tumori, Milano, Italy;7. Radiotherapy, ASL TO4 Ospedale di Ivrea, Italy;8. Radiotherapy, Centro AKTIS Diagnostica e terapia, Napoli, Italy;9. Medical Physics, Fondazione IRCCS Istituto Nazionale Tumori, Milano, Italy;10. Department of Physics, Regina Elena National Cancer Institute, Rome, Italy;11. Medical Physics Department, Candiolo Cancer Institute – FPO, IRCCS, Italy;12. Medical Physics, ASL TO4, Ospedale di Ivrea, Italy;13. UNIV Hematology and Hemato-Oncology, Università degli Studi di Milano, Italy;1. Dipartimento di Scienze Biomediche, Sperimentali e Cliniche, Università degli Studi di Firenze, Italy;2. Azienda Ospedaliero Universitaria Careggi, Firenze, Italy;3. INFN-Dipartimento di Ingegneria Industriale, Università di Roma “Tor Vergata”, Roma, Italy
Abstract:Background and purposeTo determine the optimum combination of treatment parameters between pitch, field width (FW) and modulation factor (MF) for extremity sarcomas in tomotherapy.Materials and methodsSix patients previously treated for extremity sarcomas (3 arms and 3 legs) with tomotherapy were included in this study. 288 treatment plans were recalculated, corresponding to all combinations between 2 FW (2.5 and 5 cm), 4 MF (1.5, 2, 2.5 and 3) and 6 pitches (0.215, 0.287, 0.43 and 3 off-axis pitches). The treatment parameters (MF, FW or pitch) are modified between each plan, and the calculation is relaunched for 400 iterations, without modifying the optimisation constraints of the plan under which the patient has been treated.ResultsWe suggest eliminating the 0.43 pitch and never combining a 0.215 pitch with an MF ≤ 2. We also do not recommend using an MF = 1.5 unless treatment time is an absolute priority over plan quality. We did not see any advantage in using Chen off-axis pitches, except for targets far from the axis (>15 cm) treated with a high pitch. A combination of MF = 2/FW = 5 cm/pitch = 0.287 gives plans of acceptable quality, combined with reduced treatment times. These conclusions are true only for extremity sarcomas treated in 2 Gy/fraction.ConclusionsWe have shown that the choice of pitch/MF/FW combination is crucial for the treatment of extremity sarcomas in tomotherapy: some produce good dosimetric quality with a reduced irradiation time, while others may increase the time without improving the quality.
Keywords:Tomotherapy planning  Sarcomas  Pitch  Modulation factor  Field width
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号