Efficacy of single versus multiple exposure by electromagnetic modalities on gram-negative and positive bacterial strains in an in-vitro model |
| |
Authors: | Snehil Dixit Irfan Ahmad Kumar Gular Refaat A. Eid Ravi Shankar Reddy Ivana Leão Ribeiro Mohammed Abohashrh Mastour Saeed Alshahrani Jaya Shanker Tedla Nitin Arun Dixit |
| |
Affiliation: | 1. Department of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia;2. Department of Clinical Laboratory Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia;3. Department of Pathology, College of Medicine, King Khalid University, Abha, Saudi Arabia;4. Department of Basic Medical Sciences, College of Applied Medical Sciences, King Khalid University, Saudi Arabia;5. Senior Consultant Radiologist, Sahara India Medical Institute, Gomti Nagar, Lucknow, Uttar Pradesh, India;6. Department of Kinesiology, Faculty of Health Sciences, Universidad Católica del Maule, Talca, Chile |
| |
Abstract: | ObjectivesThe primary purpose of the recent experiment was to scrutinize the dissimilarity between single and multiple exposures by electrotherapeutic modalities to determine the development of Gram-positive and Gram negative bacteria spectrum.Material and methodsBacterial strains employed in this study were Gram-negative bacteria such as Pseudomonas aeruginosa, Escherichia coli, and Klebsiella pneumonae and Gram-positive bacteria such as Staphylococcus aureus, Staphylococcus saprophyticus and Streptococcus pyogenes. Fluence for Low level laser therapy (LLLT) (810 nm) was 40 J/cm2 for 80 s, for microwave (MWD) a dosage of 100-Watt with duration of 5 min and for magnetic field therapy (MT) duration of 30 min with 100% intensity was used.ResultsRepeated Measures of analysis of variances (RANOVA) for within-subject effects was used to detect a global significant change within the means at dissimilar time points. The experiments of within-subjects revealed a significant difference within groups, df of (3, 40), F value of 39.38 and a p value less than 0.001, representing a significant variation between the three groups between pre and post exposures. There was a significant variation between single exposure and multiple exposures in the experimental sample’s pre-post between the four groups with df (1, 40) f value of 2943.69 and p value less than 0.001. Scanning and Transmission electron microscopy images were also taken into account to determine the extent of damage caused to the bacterial cells surface topography in Gram negative and Gram positive spectrums.ConclusionThe study demonstrated that single high exposure with the LLLT appears to have the most emphatic effect followed by exposure by MWD and MT. |
| |
Keywords: | Low level laser therapy Magnetic therapy Microwave diathermy Gram negative bacteria Gram positive bacteria Photo-inhibitory Electromagnetic spectrum |
本文献已被 ScienceDirect 等数据库收录! |
|