首页 | 本学科首页   官方微博 | 高级检索  
     


The effect of the elongation of the proximal aorta on the estimation of the aortic wall distensibility
Authors:Pagoulatou  Stamatia Z.  Ferraro  Mauro  Trachet  Bram  Bikia  Vasiliki  Rovas  Georgios  Crowe  Lindsey A.  Vallée  Jean-Paul  Adamopoulos   Dionysios  Stergiopulos   Nikolaos
Affiliation:1.Laboratory of Hemodynamics and Cardiovascular Technology (LHTC), IBI-STI, Ecole Polytechnique Fédérale de Lausanne (EPFL), MED 3 2226 (Batiment MED), Station 9, 1015, Lausanne, Switzerland
;2.Biofluid, Tissue and Solid Mechanics for Medical Applications (BIOMMEDA), Institute of Biomedical Technology, Ghent University, Ghent, Belgium
;3.Department of Radiology and Medical Informatics, Hôpitaux Universitaires de Genève (HUG), Geneva, Switzerland
;4.Department of Cardiology, Hôpitaux Universitaires de Genève (HUG), Geneva, Switzerland
;
Abstract:

The compliance of the proximal aortic wall is a major determinant of cardiac afterload. Aortic compliance is often estimated based on cross-sectional area changes over the pulse pressure, under the assumption of a negligible longitudinal stretch during the pulse. However, the proximal aorta is subjected to significant axial stretch during cardiac contraction. In the present study, we sought to evaluate the importance of axial stretch on compliance estimation by undertaking both an in silico and an in vivo approach. In the computational analysis, we developed a 3-D finite element model of the proximal aorta and investigated the discrepancy between the actual wall compliance to the value estimated after neglecting the longitudinal stretch of the aorta. A parameter sensitivity analysis was further conducted to show how increased material stiffness and increased aortic root motion might amplify the estimation errors (discrepancies between actual and estimated distensibility ranging from − 20 to − 62%). Axial and circumferential aortic deformation during ventricular contraction was also evaluated in vivo based on MR images of the aorta of 3 healthy young volunteers. The in vivo results were in good qualitative agreement with the computational analysis (underestimation errors ranging from − 26 to − 44%, with increased errors reflecting higher aortic root displacement). Both the in silico and in vivo findings suggest that neglecting the longitudinal strain during contraction might lead to severe underestimation of local aortic compliance, particularly in the case of women who tend to have higher aortic root motion or in subjects with stiff aortas.

Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号